Skip to main content

OBDSTAR Program Ford Ranger 2015 All Keys Lost

How to add a new key and program all keys lost for Ford Ranger 2015 using OBDSTAR X300 DP PLUS (Key Master DP plus) via OBD.

Add A Spare Key Procedure:
Connect x300 dp plus with vehicle
Select Immobilizer->Ford/Lincoln->Ford->Immobilizer->Ranger->2015 up->Type 1(Priority Select)->Program keys

obdstar-x300-dp-plus-ford-ranger-2015-akl-1 (2)

obdstar-x300-dp-plus-ford-ranger-2015-akl-3 (2)

obdstar-x300-dp-plus-ford-ranger-2015-akl-4 (2)

obdstar-x300-dp-plus-ford-ranger-2015-akl-5 (2)

obdstar-x300-dp-plus-ford-ranger-2015-akl-6 (2)

Communicating
Press Emergency flasher switch
Open and close the driver door once

obdstar-x300-dp-plus-ford-ranger-2015-akl-7 (2)

Detect current number of keys: 2
Connecting the server

obdstar-x300-dp-plus-ford-ranger-2015-akl-8 (2)

Reading data

obdstar-x300-dp-plus-ford-ranger-2015-akl-9 (2)

Insert a new key into ignition lock, switch ignition on, Press ENTER to continue

obdstar-x300-dp-plus-ford-ranger-2015-akl-10 (2)

Program 1st key success

obdstar-x300-dp-plus-ford-ranger-2015-add-key-11 (2)

Test remote control and start vehicle

obdstar-x300-dp-plus-ford-ranger-2015-add-key-12 (2)
obdstar-x300-dp-plus-ford-ranger-2015-add-key-13 (2)

X300 DP plus All Key Lost Procedure:
Select Immobilizer->Ford/Lincoln->Ford->Immobilizer->Ranger->2015 up->Type 1(Priority Select)->All Keys Lost

obdstar-x300-dp-plus-ford-ranger-2015-add-key-14 (2)

obdstar-x300-dp-plus-ford-ranger-2015-add-key-7 (2)

Communicating
Press Emergency flasher switch
All keys will be erased. Require at least 2 keys to be programmed

obdstar-x300-dp-plus-ford-ranger-2015-add-key-8 (2)
obdstar-x300-dp-plus-ford-ranger-2015-add-key-9 (2)

Detect current number of keys: 3
Connecting the server
Reading data
Complete the following procedure to start engine
-Switch ignition off
-Switch ignition on with key 1 for 3 sec, and then switch off and remove key
-Switch ignition on with key 2 for 3 sec, and then switch off and remove key
-If you want to add more keys, repeat procedure 3, complete

obdstar-x300-dp-plus-ford-ranger-2015-add-key-10 (2)

Program key until completed.
Test remote and start vehicle with new keys.
Done.

Comments

Popular posts from this blog

How to setup BMW ISTA/P Loader for ICOM A2 ENET cable K+DCAN adapter

The text here, as a user manual of BMW ISTA/P Loader / ICOM Emulator,  is aimed to help those puzzled with ISTA/P Loader setup for  ICOM A2 , ENET cable, K+DCAN  USB interface. Note: all info here not original, shared by a forum member So try at your own risk! Main content: Part 1 – Compatible device Part 2 – Latest ISTA/P Loader update information Part 3 – How to install ISTA/P Loader v4.x Part 4 – How to use  ISTA/P loader with ICOM A2, K+DCAN cable, ENET cable Part 5 – How to shut down ISTA/P Part 1 – Compatible device: ISTA/P Loader compatible with ICOM A2 (OEM or clone), K+DCAN USB and ENET   Part 2 – Latest ISTA/P Loader update information: NEWEST – ISTA/P Loader V4.8  update info: Free download BMW ISTA-P Loader V4.8.7 to get all new info yourself …… ISTA/P Loader V4.2 update info: Custom resolution option added Improved detection of bmw scan tool ISTA-P install location. Improved compatibility with windows 10 Code...

JOHN DEERE DIAGNOSTIC OPTIONS

JOHN DEERE DIAGNOSTICS John Deere has recently been in the news because of their strict opposition to allowing farmers, equipment owners, and repair shops access to the information they need to repair and maintain their vehicles. If you read the main stream news, you would be left to believe that John Deere diagnostic with a computer is impossible. Well, we are here to help dispel that myth and give some more exposure to some tools that actually do perform diagnostics on John Deere. There are actually several solutions in the market, some of which we will cover in this post. JOHN DEERE EDL AND SERVICE ADVISOR The very best solution in the market is what the dealers use. John Deere dealers use a combination of PC-based computer with two critical components – John Deere Service Advisor software and the John Deere EDL v3 Adapter . The EDL v3 adapter looks like the picture shown below. It comes with a hard carry case, the adapter itself, a 9-pin connector, and the USB ca...

PIWIS Tester Technical Information

WF51 – Re-coding Instrument Cluster (Workshop Campaign) Important: CRITICAL WARNING – This campaign includes steps where control unit(s) in the vehicle will be programmed with the PIWIS Tester. The vehicle voltage must be maintained between 13.5 volts and 14.5 volts during this programming. Failure to maintain this voltage could result in damaged control unit(s). Damage caused by inadequate voltage during programming is not a warrantable defect. The technician must verify the actual vehicle voltage in the PIWIS Tester before starting the campaign and also document the actual voltage on the repair order. Please refer to Equipment Information EQ1401 for a list of suitable battery chargers/power supplies which should be used to maintain vehicle voltage. Model Year: 2015 Vehicle Type: Cayenne S E-Hybrid (92A) Concerns: Instrument cluster Information: The instrument cluster on the affected vehiclesmay have been coded using an incorrect coding rule. As a result, there...