PIWIS Tester Technical Information

WF51 – Re-coding Instrument Cluster (Workshop Campaign)
Important: CRITICAL WARNING – This campaign includes steps where control unit(s) in the vehicle will be
programmed with the PIWIS Tester. The vehicle voltage must be maintained between 13.5 volts and 14.5
volts during this programming. Failure to maintain this voltage could result in damaged control unit(s). Damage caused by inadequate voltage during programming is not a warrantable defect. The technician
must verify the actual vehicle voltage in the PIWIS Tester before starting the campaign and also document the actual voltage on the repair order. Please refer to Equipment Information EQ1401 for a list of suitable battery chargers/power supplies which should be used to maintain vehicle voltage.
Model Year: 2015
Vehicle Type: Cayenne S E-Hybrid (92A)
Concerns: Instrument cluster
Information: The instrument cluster on the affected vehiclesmay have been coded using an incorrect
coding rule. As a result, there is a possibility that the range on remaining fuel will be calculated incorrectly and an incorrect range will be shown on the display when driving extensively at full load.
The fuel-level indicator always shows the correct level.
Action Required: Re-code instrument cluster.
Affected Vehicles: The VIN(s) can be checked by using PIWIS Vehicle Information link to verify if the campaign affects the vehicle. This campaign is scope specific to the VIN! Failure to verify in PIWIS may result in an improper repair. This campaign affects 160 vehicles in North America.
Tools:
* 9818 – Porsche Piwis Tester with PIWIS Tester test software version 15.700 (or higher) installed.
* Battery Charger/Power Supply – Suitable for AGM Type batteries, recommended current rating of
70A fixed voltage 13.5V to 14.5V. Refer to Equipment Information EQ-1105.
Claim Submission: See Attachment “A”.
Preliminary work
NOTICE
* Coding will be aborted in the event of low voltage.
* Increased current draw during diagnosis can cause a drop in voltage, which can result in one ormore fault entries and the abnormal termination of the coding process.
* Before getting started, connect a suitable battery charger with a current rating of at least 70 A to the jump-start terminals in the engine compartment.
NOTICE
Coding will be aborted if the Internet connection is unstable.
* An unstable Internet connection can interrupt communication between PIWIS Tester II and the vehicle
communication module (VCI). As a result, coding may be aborted.
* During control unit programming, always connect PIWIS Tester II to the vehicle communicationmodule
(VCI) via the USB cable.
1 Connect Battery Charger/Power Supply – Suitable for AGM Type batteries, recommended current
rating of 70A fixed voltage 13.5V to 14.5V. Refer to Equipment Information EQ-1105.
2 9818 – PIWIS Tester II must be connected to the vehicle communication module (VCI) via the USB
cable. Then connect the communication module to the vehicle and switch on the PIWIS Tester.
3 On the PIWIS Tester start screen, call up the ? ‘Diagnostics’ menu and select the vehicle type ?
‘Cayenne’ ? ’92A’.
The diagnostic application is then started and the control unit selection screen is populated.
Re-coding instrument cluster
Information
The procedure described here is based on the Professional Diagnostic Tool PIWIS Tester II software version 15.700.
The PIWIS Tester instructions take precedence and in the event of a discrepancy, these the instructions that must be followed.
A discrepancy may arise with later software versions for example.
Work Procedure:
8-1
1 Select ? ‘Instrument cluster’ in the control unit selection screen (? ‘Overview’ menu) and press ?>>“ to confirm your selection => Control unit selection – Instrument cluster.
2 When the question “Create Vehicle Analysis Log (VAL)?” appears, either press ?F12“to create a VAL
or press ?F11“ if you do not want to create a VAL.
3 Press?>>“ to acknowledge the message informing you that campaigns for the vehicle are stored in the
PIWIS information system.
4 Once the instrument cluster has been found and is displayed in the overview, select the ?
‘Codings/adaptations’ menu.Instrument cluster – Automatic coding
5 Select the ? ‘Automatic coding’ function and press ?>>“ to start coding?
8-2
8-3
6 When coding is complete, the message “Coding has been completed successfully” is displayed and a tick appears in the ‘Status’ box ? Coding successful. If coding is not completed successfully (error
message “Coding was not completed successfully”),coding must be repeated.
7 Once coding has been completed successfully, press ?>>“ to return to the start page of the ?
‘Codings/adaptations’ menu.
8 Select the ? ‘Overview’ menu and press ?<<“ to return to the control unit selection screen.
Reading out and erasing faultmemories
WorkProcedure:
1 In the control unit selection screen (? ‘Overview’ menu), press ?F7“to call up the Additional menu.
2 Select the function “Read all fault memories and erase if required” and press ?>>“ to confirm
? Erasing fault memories.
The fault memories of the control units are read out.
8-4
3 Once you have read out the fault memories, delete the fault memory entries by pressing ?F8“.
4 Press ?F12“ (“Yes”) in response to the question as to whether you really want to erase all fault
memory entries.
The faults stored in the fault memories of the various control units are deleted.
Information
If the faultmemories of individual control units (e.g. faultmemories of the control units DME, Adaptive
Cruise Control (ACC), etc.) cannot be erased, proceed as follows:
* Switch off ignition.
* Disconnect the PIWIS Tester diagnostic connector from the diagnostic socket.
* Lock the vehicle using the driver’s key.
* Wait approx. 1 minute before unlocking the vehicle again.
* Plug the PIWIS Tester diagnostic connector into the diagnostic socket again and restore communication
with the vehicle.
* Read out the fault memories of these control units again and erase the fault memories separately.
If control units are found to have faults that cannot be erased and are not caused by control unit programming, these faults must be found and corrected. This work cannot be invoiced under the workshop campaign number.
5 Once you have erased the fault memories, select the ? ‘Overview’ menu to return to the control unit selection screen => Control unit selection.
8-5
Calibrating electric machine
Information
The electric machine must generally be calibrated after the fault memories of the OBD-relevant control
units or the fault memories of all control units have been erased. The rotor position (phase angle) and rotor temperature are stored during calibration of the electric machine.
Work Procedure:
1 Press and hold the brake pedal.
2 Turn the ignition key in the ignition lock to position 2 (terminal 50 – engine start) and hold it at this position for about 2 to 3 seconds. Calibration of the electric machine is clearly audible. Calibration is complete once the calibration noise can no longer be heard.
3 Release the ignition key and move it to position 1 (ignition on).
Subsequent work
Work Procedure:
1 Switch off ignition.
2 Disconnect the PIWIS Tester from the vehicle.
3 Switch off and disconnect the battery charger.
4 Enter the workshop campaign in the Warranty and Maintenance booklet.
Attachment “A”: ClaimSubmission – Workshop CampaignWF51
Warranty claims should be submitted via WWS/PQIS.
Open campaigns may be checked by using either the PIWIS Vehicle Information system or through PQIS
Job Creation.
Labor, parts, and sublet will be automatically inserted when Technician is selected in WWS/PQIS. If
necessary, the required part numbers will need to be manually entered into warranty system by the dealer administrator
Working time:
Re-coding instrument cluster
Includes: Connecting and disconnecting battery charger
Connecting and disconnecting PIWIS Tester
Reading out and erasing fault memories
Calibrating electric machine
Labor time: 19 TU
=> Damage codeWF51 066 000 1
Important
https://medium.com/@obd2scanner/piwis-tester-ii-is-fully-operational-diagnostic-equipment-ab08ae21ae48

Comments

Popular posts from this blog

Xprog 6.12 5.84, 5.74, 5.60, 5.55, 5.51, 100% Works Software Free Download

Free download the newest Xprog V6.12 , XPROG 5.84 , XPROG 5.74 , XPROG 5.60 , Xprog 5.55 and XPROG 5.51. 1.XPROG-M 6.12 free download: Link 1: https://mega.nz/#!625RxAqJ!Y7IInI5ZhG3titLMPnFOvALbOa2RHIp7ENG2o4PIzag Password: No need Link 2: https://share.weiyun.com/5m5Vkw0 Password: fxo5qz Xprog 6.12 XPROG V6.12 installation video: XPROG-M V6.12 Using tips and installation guide: https://www.obd2tool.com/blog/2020/02/29/how-to-use-and-install-xprog-v6-12-on-win-xp-win7win8/ 2. XPROG V5.84 free download: https://mega.nz/#!7vpDwQ4D!MrdDW0tVf-6-wXtGKqpUmj7CA2HFlFlMf5AeNvYgRbI Tips for installing Xprog V5.84. 1.Disable anti-virus program when downloading software and running software. 2.Uninstall all the software and USB drivers of the old version xprog-box on your computer, then install the new XPROG5.84 software. 3.Run 5.84 Regsisty program for several timeswhen installing software 4.Run 5.84 Regsisty file for 2 times before you run software everytime .

How to setup BMW ISTA/P Loader for ICOM A2 ENET cable K+DCAN adapter

The text here, as a user manual of BMW ISTA/P Loader / ICOM Emulator,  is aimed to help those puzzled with ISTA/P Loader setup for  ICOM A2 , ENET cable, K+DCAN  USB interface. Note: all info here not original, shared by a forum member So try at your own risk! Main content: Part 1 – Compatible device Part 2 – Latest ISTA/P Loader update information Part 3 – How to install ISTA/P Loader v4.x Part 4 – How to use  ISTA/P loader with ICOM A2, K+DCAN cable, ENET cable Part 5 – How to shut down ISTA/P Part 1 – Compatible device: ISTA/P Loader compatible with ICOM A2 (OEM or clone), K+DCAN USB and ENET   Part 2 – Latest ISTA/P Loader update information: NEWEST – ISTA/P Loader V4.8  update info: Free download BMW ISTA-P Loader V4.8.7 to get all new info yourself …… ISTA/P Loader V4.2 update info: Custom resolution option added Improved detection of bmw scan tool ISTA-P install location. Improved compatibility with windows 10 Code improvements & minor bug

Free download witech 2 v17.04.27 for micropod 2 Chrysler diagnostic tool

Free download  chrysler diagnostic software v17.04.27: https://mega.nz/#F!aHoHnIIK!xMk41bPFQ8zzZexxRcq1RA From mhhauto. Free download witech 2 v17.03.10 https://mega.nz/#!BNAjnAQB!AWiM7QTImGt5n0XvgqNLF6rZ87gFQ4GqC9rl4dOtYcY from obd2tool.com engineer Tested more stable than witech 2 v17.04.27 Compatible with HQ China witech micropd 2 and original one windows 7 32bit or 64bit Diagnosis: Confirmed Programming online/offline: Confirmed Multi-languages: English, French, Spanish, German, Italian, Russian, Japanese, Korean and Chinese Workable cars: Chrysler, Jeep, Dodge, Fiat witech 2 v17.04.27 win7 installation: *** Do not connect to network when you use the device. First connect MicroPodII to vehicle, if the red indicator turns on, then connect to laptop and run software. Read this article: how-to solve MicropodII with serial xxxx not registered? DRBIII Emulator if possible? witech micropd 2: DRB III emulator confirmed working, but it doesn’t cont