Skip to main content

The power light on the CANdi module doesn’t come on when connected to the Tech 2?

The power light on the CANdi module doesn’t come on when connected to the Tech 2? If that’s what you mean mine does not light up either. I think they should flash when linked to the car’s computer as that means the CANdi module is communicating. Bosch instructions;
Tech 2 CANdi User’s Guide
P/N 08002749 03/07 ?2007 Robert Bosch LLC, U.S.A. All rights reserved.
The Controller Area Network Diagnostic Interface (CANdi) is an in-cable module that works with the existing Tech 2 components including the VCI, cables, and adapters.
Installed, the CANdi module is fully backward compatible with current tester functionality. The module powers up in a way that makes it transparent to the user. That is, unless the GM Tech 2 enables features specific to the CANdi module, all signal lines function as they do without the
CANdi module. This allows the existing Tech 2 software to be used with no changes, whether or not the CANdi module is installed.
The primary function of the CANdi module is to add CAN capability to the Tech 2 tester. The following list summarizes the basic characteristics of the CANdi module: Supports simultaneous communications on three CAN buses Provides high speed UART communications with the Tech 2.
The Tech 2 commands the CANdi module operation.
When installed, the CANdi module does not interfere with any diagnostic procedure currently performed using the Tech 2. The usage of a CANdi module does not require any physical changes to the Tech 2, its cables, or adapters. The module operates in transparent mode until awakened by the Tech 2. Upon initialization, the CANdi module operates under master control of the Tech 2. All functionality is determined by the Tech 2 application software which is loaded on the Tech 2’s program card.
The CANdi module always operates in slave mode to the Auto Scanner Tool Tech 2, responding in high speed SAE J1708 to the tester.
Physical Interface and LED CANdi connects to the Tech 2 by way of the existing Data Link Connector (DLC) Burndy Connector. The vehicle side connection remains unchanged using the existing adapter to interface between the Burndy connector and the SAE J1962 connector. When functioning properly, CANdi’s LED flashes. In the event of a problem, the LED will be constantly illuminated.
Warranty and Technical Service Included with your system is a Warranty Card that must be submitted to Vetronix for activation of the two-year warranty. For technical assistance, please contact Vetronix Tech Support at Obd2tool.com.

Comments

Popular posts from this blog

Xprog 6.12 5.84, 5.74, 5.60, 5.55, 5.51, 100% Works Software Free Download

Free download the newest Xprog V6.12 , XPROG 5.84 , XPROG 5.74 , XPROG 5.60 , Xprog 5.55 and XPROG 5.51. 1.XPROG-M 6.12 free download: Link 1: https://mega.nz/#!625RxAqJ!Y7IInI5ZhG3titLMPnFOvALbOa2RHIp7ENG2o4PIzag Password: No need Link 2: https://share.weiyun.com/5m5Vkw0 Password: fxo5qz Xprog 6.12 XPROG V6.12 installation video: XPROG-M V6.12 Using tips and installation guide: https://www.obd2tool.com/blog/2020/02/29/how-to-use-and-install-xprog-v6-12-on-win-xp-win7win8/ 2. XPROG V5.84 free download: https://mega.nz/#!7vpDwQ4D!MrdDW0tVf-6-wXtGKqpUmj7CA2HFlFlMf5AeNvYgRbI Tips for installing Xprog V5.84. 1.Disable anti-virus program when downloading software and running software. 2.Uninstall all the software and USB drivers of the old version xprog-box on your computer, then install the new XPROG5.84 software. 3.Run 5.84 Regsisty program for several timeswhen installing software 4.Run 5.84 Regsisty file for 2 times before you run software everytime . ...

How to setup BMW ISTA/P Loader for ICOM A2 ENET cable K+DCAN adapter

The text here, as a user manual of BMW ISTA/P Loader / ICOM Emulator,  is aimed to help those puzzled with ISTA/P Loader setup for  ICOM A2 , ENET cable, K+DCAN  USB interface. Note: all info here not original, shared by a forum member So try at your own risk! Main content: Part 1 – Compatible device Part 2 – Latest ISTA/P Loader update information Part 3 – How to install ISTA/P Loader v4.x Part 4 – How to use  ISTA/P loader with ICOM A2, K+DCAN cable, ENET cable Part 5 – How to shut down ISTA/P Part 1 – Compatible device: ISTA/P Loader compatible with ICOM A2 (OEM or clone), K+DCAN USB and ENET   Part 2 – Latest ISTA/P Loader update information: NEWEST – ISTA/P Loader V4.8  update info: Free download BMW ISTA-P Loader V4.8.7 to get all new info yourself …… ISTA/P Loader V4.2 update info: Custom resolution option added Improved detection of bmw scan tool ISTA-P install location. Improved compatibility with windows 10 Code...

PIWIS Tester Technical Information

WF51 – Re-coding Instrument Cluster (Workshop Campaign) Important: CRITICAL WARNING – This campaign includes steps where control unit(s) in the vehicle will be programmed with the PIWIS Tester. The vehicle voltage must be maintained between 13.5 volts and 14.5 volts during this programming. Failure to maintain this voltage could result in damaged control unit(s). Damage caused by inadequate voltage during programming is not a warrantable defect. The technician must verify the actual vehicle voltage in the PIWIS Tester before starting the campaign and also document the actual voltage on the repair order. Please refer to Equipment Information EQ1401 for a list of suitable battery chargers/power supplies which should be used to maintain vehicle voltage. Model Year: 2015 Vehicle Type: Cayenne S E-Hybrid (92A) Concerns: Instrument cluster Information: The instrument cluster on the affected vehiclesmay have been coded using an incorrect coding rule. As a result, there...