Skip to main content

Posts

Showing posts from 2019

WOYO PDR009 1500W Induction Heater Paintless Dent Metal Repair Removing Tool

Induction Heater For Removing Dents WOYO PDR009 Sheet Metal Repair Tools Note: This device is designed specifically to be used with dents on Aluminum car bodies. Specification: (1)100~120V (US Plug) Model: WOYO PDR009 Input Voltage: 100~120 V Input Current: 14 A Output Power: ≈ 1500 W Output Voltage: 50~60 V Output Current: 60 A Plug Size: US Plug Package Size(L*W*H):39 x 33 x 13 cm Application: Soft Dent, Dent In Non-marginal Area (2)220~240V (EU Plug) Model: WOYO PDR009 Input Voltage: 220~240 V Input Current: 7 A Output Power: ≈ 1500 W Output Voltage: 50~60 V Output Current: 55 A Plug Size: EU Plug Package Size(L*W*H):39 x 33 x 13 cm Application: Soft Dent, Dent In Non-marginal Area (Note: Please leave us a message about your prefer Voltage,or we will send by random.) (3)Package Included: 1 x PDR Main 1 x Main Cable(3M) 1 x Power Cable(1.8M) 1 x Repair Handle 1 x Tool Case   (4)Features: *  Certifcate CE FCC ROHS PSE. *  Independent

Smart V31.11 IMMO Upgrade on OBDSTAR X300 DP Plus and X300 PRO4 and X300 DP

Smart V31.11 IMMO Upgrade on OBDSTAR X300 DP Plus and  X300 Pro4 and X300 DP www.obd2tool.com sales@obd2tool.com

What the difference between C5 and other Mercedes star diagnostic

Hardware: The hardware of  Mercedes star diagnostic C5 is better and stable than MB Star C4; it has a qualitative improvement in hardware and software by authorization of diagnostic interface to control the software. 1.OS: Windows Embedded Standard 7(32bit) 2.Processor: ArrandaieCeleron P4500 oder P4505(38W TDP) 3.Memory: 4G hard disk with 256GB SSD 4.Display: 128*64 PX 5.Battery: 40 minutes (When CPU capacity to 60%) 6.Weight: 1.9KG 7.Network connection: WLAN : IEEE802.11 a/b/g/n2.4+5GHZ The way to connect: support wireless connection via 1000M workshop switches, also support wired connection. Software: All diagnostic software is loaded into the Xentry Connect multiplexer itself. The management software can be installed on any computer with Windows 7 – 32-bit or Windows 8 – 32-bit and serves only for communication with the multiplexer The licensing system is reworked – now licenses are stored on MB servers – Any license changes are tracked by the multiplexer when co

How to Solve VVDI MB can’t read ESL ELV Data Error

Obd2tool.com engineer offers the 100% working solution to Xhorse VVDI MB can’t read Read ESL /ELV data when using together with ESL /ELV emulator. That is you don’t need to return back the emulator. Firstly, please download XHORSE ESL file https://mega.nz/#!sIYxjQSL!mKUNAQ6mSVR6xseZIncXf-Jx1ofgl69t2i1W1TpsQ18 No password. Procedure: Connect ESL /ELV emulator to the VVDI MB and one computer. Click on “Read ESL data”. And EIS can’t read successfully. Click on “Load EIS data” to load ” XHORSE ESL file” downloaded above. Click on “Write” until 100%. Again, click on “Read EIS data” until 100%. And do like the following image (hold on for 10 seconds) Read EIS data successfully.

OBDSTAR X300 PRO 4 vs X300 DP PAD PLUS

X300 Pro4 key programmer  is an all-purpose immobiliser programming device meticulously designed by OBDSTAR for locksmith. The passage mainly introduce the differences of OBDSTAR X300 PRO 4 and OBDSTAR X300 DP PLUS Package includes:

GM Tech2 Scanner VCI, Keypad, CANdi and RS232 Self Test Instructions

Manual: How to do  GM Tech 2 Scanner self test step-by-step VCI self test Keypad self test CANdi self test RS-232 self test Follow the instruction in detail… Part 1: Tech2 VCI self test Insert the GM card Connect the adapter and ready for the self test Go to the main menu and select F4: Tool options F3: Self test Exit to continue Select the function for self test Here, press F2: Automated VCI The VCI module self test result Passed VCI selftest. Part 2: GM Tech II Keypad self test Go to the Tech 2 menu and select F4: Tool options Then F3: Self test Before running the Tech 2 self test: (1) Candi cannot be connected (2) Aldl loopback should be connected (GM3000109) (3) Failure to follow these instructions may invalidate the self test F3: Selectable main pcb Press Keypad And press key Note: In the last image, the actual key pressed is F0 and the final result is PASS – that’s normal When you test the keypad, pr

Compare New Xprog M V6.12 with Old Xprog M V5.84 ECU Programmer

New Xprog V6.12 more functions than old version,New Generation Hardware, runs more steady and faster than old version. Now, we’ll talk about the difference: 1.Items in parcel 2.PCB 3.Authorization in detail.. 1. Xprog 5.84 and 6.12 full kit Note: Xprog 6.12 comes with 4 new adapters: ADP-0006 M35080 ICP, QFP64 MC908AZ/AS603K85K, ADP-0019 Rev. B, QO18S714 Xprog 6.12 full adapter list: ADP-0019 Rev.B —-New! ADP-0006 M35080 ICP adapter —New! QFP64 MC908AZ/AS60 3K85K adapter —New! QO18S714 —New! ADP-0001 TMS370 PLCC28 programming adapter ADP-0002 TMS370 PLCC44 programming adapter ADP-0003 TMS370 PLCC68 programming adapter ADP-0004 Motorola HC05B/X PLCC52 programming adapter ADP-0005 Motorola HC05B/X QFP64 programming adapter ADP-0006 ST M35080 in-circuit programming adapter ADP-0008 TMS374 family in-circuit programming adapter ADP-0009 MC68HC05V12 programming adapter ADP-0010 TMS374 on-board programming adapter ADP-0011 HC11EA9/E9